No. | Device Name | Picture | Index | Use |
---|---|---|---|---|
1 | Electronic universal testing machine |
Maximum tension: 2000KN
|
Mechanical properties of stretching, bending, compressive strength test | |
2 | Heat aging box |
Temperature: -70 ~ 150 ℃
|
High and low temperature heat aging performance test | |
3 | UV aging box |
Temperature: 10 ~ 70 ℃
|
UV aging tests | |
4 | Salt spray aging test machine |
Test temperature: <63 ℃
|
Anti-aging properties of salt spray corrosion test | |
5 | High temperature chamber |
Maximum temperature: 500 ℃
|
High Temperature Performance Test | |
6 | Resistance Tester |
Resistance: 103-1012 Ohm
|
Resistance Test | |
7 | X-ray nondestructive testing |
Field: 100mm
|
NDT | |
8 | Ultrasonic flaw detector |
Detection range: 0.1-8000mm
|
NDT | |
9 | Rockwell hardness |
Digital
|
Hardness Testing | |
10 | Universal friction and wear tester |
Test force: 10-1000N
|
Friction and wear properties | |
11 | Electro-hydraulic servo fatigue testing machine |
Maximum load: ± 1000KN
|
Dynamic and static mechanical properties | |
12 | Rotating bending fatigue testing machine |
Runout: ≤0.01mm
|
Bending fatigue test | |
13 | High-frequency fatigue testing machine |
Maximum load: 500KN
|
Fatigue characteristics of the sample under tension and compression and alternating flowers and the sine wave | |
14 | Electronic high-temperature creep rupture strength testing machine |
Maximum load: 100KN
|
High temperature creep relaxation tests | |
15 | Drop hammer impact test machine |
Maximum impact energy: 30000J
|
Impact Performance Test | |
16 | Low temperature impact test instrument |
Temperature range: 30 ~ -60 ℃
|
||
17 | Thermal Mechanical Analyzer |
temperature range:
|
Thermo-mechanical properties of materials | |
18 | Dynamic Mechanical Analyzer |
Frequency Range:
|
Tg test material | |
19 | Laser thermal conductivity meter |
temperature range:
|
Thermal diffusivity, thermal conductivity measurement | |
20 | Dilatometer |
temperature range:
|
Linear expansion coefficient measurement | |
21 | Differential Scanning Calorimetry |
temperature range:
|
Thermal performance | |
22 | TGA |
Resolution: 0.1 g
|
Thermal performance | |
23 | Microscopic infrared absorption spectrometer |
MCT single point detector: ≥7800-600cm-11
|
Particle and fiber analysis | |
24 | Rotary flow analyzer |
Frequency Range:
|
Rheological performance analysis | |
25 | Elemental analyzer | Measuring range: C:0.03~20mg; H:0.03~3mg; N:0.03~2mg; S:0.03~6mg; O:0.03~2mg |
Content measurement sample CHNSO | |
26 | Liquid X-ray diffractometer |
High voltage stability: 0.005%
|
Microscopic observation | |
27 | Nuclear magnetic resonance spectrometer |
Time resolution: 12.5ns
|
Structural analysis of organic compounds | |
28 | Fiber tensile tester |
Load Range: 0 ~ 200 cN
|
Fiber strength, elongation test |